Application:

Industry:

Shape control of blooms, if head is bent

Steel industry

Customer / Field / Equipment manufacturer

Steelworks / Production of semi-finished steel products.

Application description

Hot blooms of different sizes travel on a roller conveyor in undefined position (not guided).

Conveyor width 1000 mm approx..

Blooms height can vary from 110 up to 280 mm.

Customer problem

The end user needs to check if the bloom head is bent to avoid damage of the subsequent descaler. As blooms of different heights are transported, also control lines (light barriers) at different heights are necessary. Manufacturer decided to build up a level control similar like a light grid. Based on the bloom height being transported, the PLC monitors the light barrier line which is expected to be interrupted and also the one lying right above. If also the superior beam is interrupted, a bow of the bloom has been detected.

Previous solution

None

Proxitron solution

5 through-beam barriers were used to create a light grid with five height levels according to bloom sizes. To avoid mutual light interference, they were horizontally staggered along the conveyor. The use of OL 19 tube was recommended to create a most defined (thin) line. Transmitter and receiver were arranged so that two side by side installed light barriers always had opposite beam direction: Emitter and receiver look alternatively from right to left and from left to right.

Advantages compared to previous solution or competition

Robust housing and reliable sensor function also at steam and spray mist and because of the high temperature environment, which usually affects common light barriers negatively.

Used accessories

Description

Swivel Stand

female connector straight S4, up to 105 °C

female connector straight S4, up to 105 °C

Type

HM 2

ST 043/3-10H

ST 043/5-10H

Art.-No.

9816B

9850W

9844Z

Do you have a similar application and would like to be advised?

Please fill out our application questionnaire for light barriers and send it to sales(at)proxitron.de. Our experts will answer you as soon as possible.

Vuoi essere informato sui prodotti attuali, sulle tendenze e molto altro ancora?
Stai informato con la nostra newsletter!

Iscriviti alla nostra newsletter